Diagnostic Menu
4 – 30 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
4
4
The following O2 Sensor Tests are available:
1) Rich-to-lean sensor threshold voltage
2) Lean-to-rich sensor threshold voltage
3) Low sensor voltage for switch time
4) High sensor voltage for switch time
5) Rich-to-lean sensor switch time
6) Lean-to-rich sensor switch time
7) Minimum sensor voltage test cycle
8) Maximum sensor voltage test cycle
9) Time between sensor transitions
10) Sensor period
11) Manufacturer specific tests
From the Dia
gnos
tic Menu:
1.
Select
O2 Monitor Tests.
=====================
View Fre eze Data
Drive Cycle Monitor
O2 Monitor Tests
Diag Monitor Tests
On-Board Systems
Vehicle Information
Diagnostic Menu
O2 Monitor Tests
•Use
UP
or
DOWN
arrow key until O2 Monitor
Test
s is highlighted.
•Press
ENTER
.
=====================
O2 Bank1 Sensor1
O2 Bank1 Sensor2
O2 Bank2 Sensor1
O2 Bank2 Sensor2
Select O2 Sensor
O2 Bank1 Sensor1
2. Select O2 Sensor.
•Use
UP
or
DOWN
arrow key until desired O2
Sensor
is highlighted.
•Press
ENTER
.
The O2 sensors located
upstream (before catalyst) may perform differently than ones located
downstream (after catalyst).
Test IDs are shown for unknown O2 sensor tests.
3. View Results of Selection.